KYN28-12 removable AC metal-clad switchgear (short for panel as below) is a new product, designed and developed by HEAG Group, based on the introduction of advanced foreign design and manufacturing technology. It will be a substitute for old fashioned metal-enclosed switchgear, such as KYN-12, JYN-12, GFC-12, etc. The panel applies to 3.6~12kV 3 phase AC 50Hz network  for receiving and distributing power energy and also for control, monito r and  protection. It can be arranged for single busbar, single busbar sectionlizing  system or double busbar. It accords with IEC62271-200 AC Metal Enclosed Switch and Control Equipment above 1kV and below 52kV IEC60694 Standard Common Clauses for HV Switchgear, DIN. VDE AC Switchgear at Rated Voltage Above 1kV, GB3906 3~35kVAC Metal Enclosed Switchgear and so on. It has perfect and reliable prevention function against misoperation.

Ambient condition

  • Ambient temperature: -10℃ ~+40℃ , daily average: ≤ 35℃;
  • Altitude: ≤1000m;
  • Relative humidity: daily average ≤ 95%, monthly average ≤ 90%;
  • Earthquake intensity:≤ 8 degree;
  • Applicable occasions should be free from inflammables, explosives, corrosives and severe vibration.

Model

electrisity control box
solar power control panel

Structure feature

The enclosure is made of aluminium-zinc plated steel sheet by CNC machine, high precise dimension, short production cycle, excellent mechanical strength and nice appearance. The busbar compartment, VCB handcart compartment, cable compartment and relay compartment are separated by metal sheet. Flexible operation for handcart movement, clear position instruction, the earthing switch allow to making short circuit current and creditable mechanical interlock. It fit with many kinds of handcart circuit breaker such as VD4, VS1 and VHY1-12 etc,and also select FK(R)N32-12 fixed load breaker switch or VC series vacuum contactor. The panel adopts air insulated, the door of circuit breaker have the function of anti- explosion, tested by internal electric arcing fault, without any welding contacts on the panel, mechanical and electrical locking design, the  product  conforms to GB 3906, GB/T11022,IEC 62271-200,DL/T404 standards , and passed domestic and Netherlandish KEMA test.

Technical specification

ItemUnitData
Ratedinsulationlevel1min power frequency(phase to earth / across open contacts)kV42/48
Lightning impulse withstand voltage   (phase to earth/across open contacts)kV75/85
Rated voltagekV12
Rated frequencyHz50/60
Rated currentA630~4000
Main busbar rated currentA1250,1600,2000,2500,4000
Branch busbar rated currentA630,1250,1600,2000,2500,3150
Rated short time withstand current(4s)kA16,20,25,31 .5,40,50
Rated peak withstand currentkA40,50,63,80,100,125
Protection degree Enclosure IP4X,  IP2X(VCB door opened)
Outline dimension(width  depth  height)mm650(800,1000)  1500(1300,1670,2000)  2200
Weightkg800~1200

Structure drawing

electrisity control box
solar power control panel

A.Busbar compartment  B.Circuit breaker compartment  C.Cable compartment  D.Metering compartment

1. Framework11. Top Cover of Busbar Comparment21. Interlock & Shutter System
2. Hinge12. Top Cover of VCB Compartment22. Earthing Switch Interlock
3. Middle Hinge13. Door of Instrument Compartment23. Left Plate of Cable Compartment
4. Rear Plate14. Contact Box24. Right Plate of Cable Compartment
5. Top Cover of Cable Compartment15. Fixed Contact25. Door of Cable Compartment
6. Post Insulator16. Fixing Plate of Aerial Socket26. PT handcart
7. Busbar Bushings17. Left Plate of VCB Compartment27. Earthing Busbar
8.A-phase Busbar18. Right Plate of VCB Compartment28. Branch Busbar
9. B-phase Busbar19. Door of VCB29. Current Transfarmer
10. C-phase Busbar20. Vacuum Circuit Breaker